Model 190
Standard Transducer
APPLICATIONS
Hydraulic SystemsMachine ToolsAerospace
FEATURES
Corrosion ResistantHigh Frequency ResponseDifferential CapabilityWide Pressure RangeWide Temperature RangeChoice of Output Levels
|
|
|
|
S P E C I F I C A T I O N S
|
|
RANGE
|
SENSITIVITY
|
ERROR BAND
|
|
+/- 15psig to +/- 1500psig (up to 25000psig on special order)
|
>2mV/V FS to 5V FS with integral amplifier
|
<+/- 0.30%FS
|
|
FREQUENCY RESPONSE
|
TEMPERATURE SENSITIVITY
|
ENVELOPE DIMENSIONS
|
|
300Hz to 20000Hz depending on range
|
< 0.005%FS/degF
|
1.5" dia. x 3.0" l
|
|
OVERLOAD WITHIN CALIBRATION
|
OVERLOAD WITHOUT DAMAGE
|
OPERATING TEMPERATURE RANGE
|
|
150%
|
200% (1000%with limit stops)
|
-67degF to +250degF (special order to +1200F)
|
| WEIGHT |
|
| 4oz. to 8oz. |
|
|
With over 50 years of experience in instrumentation design and development, we can cover any of your custom project needs.
If you wish to place an order or submit
specifications for a quotation please call us Toll Free at
(866) 446-2523
inquiries@transducer-universe.com
West Coast Research Corporation, 1527 26th Street, Santa Monica, CA 90404
|
|