Model 190
Standard Transducer
APPLICATIONS
Hydraulic SystemsMachine ToolsAerospace
FEATURES
Corrosion ResistantHigh Frequency ResponseDifferential CapabilityWide Pressure RangeWide Temperature RangeChoice of Output Levels
|
|
|
|
S P E C I F I C A T I O N S
|
|
RANGE
|
SENSITIVITY
|
ERROR BAND
|
|
+/- 15psig to +/- 1500psig (up to 25000psig on special order)
|
>2mV/V FS to 5V FS with integral amplifier
|
<+/- 0.30%FS
|
|
FREQUENCY RESPONSE
|
TEMPERATURE SENSITIVITY
|
ENVELOPE DIMENSIONS
|
|
300Hz to 20000Hz depending on range
|
< 0.005%FS/degF
|
1.5" dia. x 3.0" l
|
|
OVERLOAD WITHIN CALIBRATION
|
OVERLOAD WITHOUT DAMAGE
|
OPERATING TEMPERATURE RANGE
|
|
150%
|
200% (1000%with limit stops)
|
-67degF to +250degF (special order to +1200F)
|
| WEIGHT |
|
| 4oz. to 8oz. |
|
|
If you wish to place an order or submit
specifications for a quotation please call us Toll Free at
(310) 478-8833
transduc@transducer-universe.com
West Coast Research Corporation, 1527 26th Street, Santa Monica, CA 90404
|
|